The
2009
Model
          
is
out.....
best
in
class
Anolyte Cell Resources,  261 Arnolds Way, Crossville,TN. 38571, 931-484-1460
ACR   THINCELL PAGE
NECK
LENGTHS
TO MEET
ANY
TANKS
NEEDS.

QUICK
CONNECTS

SINGLE IN
AND OUT
NOZZLES
FOR THE
ANOLYTE
SYSTEM
THE THINCELL MOUNTS WITH 2         
STRUT STUDS
INSERT AND TWIST AT 9" APART
HANG THE CELL ON THE STUDS
AND SECURE WITH SS HARDWARE
THE THINCELL IS NOW MOUNTED
ATTACH THE 3/8" ID TUBING TO THE
ANOLYTE INLET NOZZLE
ATTACH THE 1/2" ID TUBING TO THE
ANOLYTE RETURN NOZZLE
ATTACH THE QUICK CONNECTS TO
CONNECT THE POWER CABLE
INSTALLATION COMPLETE- READY
FOR START UP
LD12H HORIZONTAL CELL SHOWN BELOW BRINGS A DIFFERENT ASPECT TO ECOATING
OUR customers are saving on Energy, Capital
and Labor using the Thincell vs. Tubular
anodes.

Energy savings reported from Field Data by
our customers shows a range of 10%-33%
lower rectifier voltage settings for the same
film build.....

Tubular Cell manufacturers can't claim this.

Thincells replace Tubular cells at a ratio of at
least 2-1. We have customers that have
replaced 32 Tubular cells with only 4
Horizontal ThinCell units.

Field proven, on every installation, ThinCells
provide the quickest installation time vs.
Tubular cells.

Lowest overhead clearance ever seen in the
industry, hands down.
All ThinCells are sealed
(pressurized), allowing unlimited
possibilities of mounting formats.

Thincells can be mounted overhead,
on the side, and on the bottom of your
e-coat tank. The most versatile cell on
the market.
One cell does it all.
you save energy on keeping your tank
at temp. Heres how.

Watts = Volts x amps

Operating Tubular cells at 195 Vdc and
200 amps equals 39 KW

Thincells require only 160Vdc and 200
amps
equals 32 KW

This is a reduction of 7 KW, which
equals less heat produced in the paint
bath. Reducing the load on the chillers.
You say you don't use Tubular cells!!
The ThinCell replaces C-Cells too...

ACR manufacturers mounting brackets
that allow mounting your cells on the
top rails of your tank.
We ship you brackets unattached,
located in the hardware package. This
saves on shipping costs, by having a
smaller crate. The brackets are
attached with 2 SS bolts to the side
rails. Very quick and strong.

Yes, ThinCells are more energy
efficient than the C-Cell. A saving of
10%+

No overhead crane required, A true one
man installation.

Exceptional anolyte flow path keeps
the anode face clean. We have all seen
the center erosion issue on the C-Cell
anodes. This is due to a poor
circulation path, combined with uneven
current distribution overt the arc of the
anode.
C-CELL USERS
ThinCell
Sizes
up to
72"
effective
The
ThinCell
can be
used in
bottom,
side and
overhead
positions
CLICK ON THE HIGHLIGHTED TOPIC FOR MORE
INFORMATION

•        2X the effective anode area as the Tubular cell.

•        All ThinCell anodes are closed top design.

•        Lowest profile on the market and only 1.5” thick.

•        Patented encapsulation provides a strong leak proof design.

•        No maintenance required.

•        Current density 8 amps/sqft continuous, 10 amps/sqft maximum.

•        Integrated anolyte delivery system.

•        Mounts to existing strut channel, no modifications required.

•        Disposable design, no maintenance, parts, or rotating anodes.

•        Light weight design enables a true one person installation.

•       
 Fully submersible.

•        Long life up to 5 years without maintenance.

•        One year warranty*

•        Energy efficient, costs less to operate than tubular cells.

•        Installs in less than 1/3 the time as tubular cells.

•        Factory support and engineering for your custom needs.

•        Fast shipping.
All ThinCell and AutoCell units are now
supplied with Stainless Steel Supply and
Return fittings at no extra charge.

The optional Heavy Duty Frames are now
standard on all ThinCell and AutoCell units.