| NECK LENGTHS TO MEET ANY TANKS NEEDS. QUICK CONNECTS SINGLE IN AND OUT NOZZLES FOR THE ANOLYTE SYSTEM |

| THE THINCELL MOUNTS WITH 2 STRUT STUDS |


| HANG THE CELL ON THE STUDS AND SECURE WITH SS HARDWARE |


| ATTACH THE 3/8" ID TUBING TO THE ANOLYTE INLET NOZZLE |

| ATTACH THE 1/2" ID TUBING TO THE ANOLYTE RETURN NOZZLE |

| ATTACH THE QUICK CONNECTS TO CONNECT THE POWER CABLE |

| INSTALLATION COMPLETE- READY FOR START UP |
| OUR customers are saving on Energy, Capital and Labor using the Thincell vs. Tubular anodes. Energy savings reported from Field Data by our customers shows a range of 10%-33% lower rectifier voltage settings for the same film build..... Tubular Cell manufacturers can't claim this. Thincells replace Tubular cells at a ratio of at least 2-1. We have customers that have replaced 32 Tubular cells with only 4 Horizontal ThinCell units. Field proven, on every installation, ThinCells provide the quickest installation time vs. Tubular cells. Lowest overhead clearance ever seen in the industry, hands down. |
| All ThinCells are sealed (pressurized), allowing unlimited possibilities of mounting formats. Thincells can be mounted overhead, on the side, and on the bottom of your e-coat tank. The most versatile cell on the market. One cell does it all. |
| you save energy on keeping your tank at temp. Heres how. Watts = Volts x amps Operating Tubular cells at 195 Vdc and 200 amps equals 39 KW Thincells require only 160Vdc and 200 amps equals 32 KW This is a reduction of 7 KW, which equals less heat produced in the paint bath. Reducing the load on the chillers. |
| You say you don't use Tubular cells!! The ThinCell replaces C-Cells too... ACR manufacturers mounting brackets that allow mounting your cells on the top rails of your tank. We ship you brackets unattached, located in the hardware package. This saves on shipping costs, by having a smaller crate. The brackets are attached with 2 SS bolts to the side rails. Very quick and strong. Yes, ThinCells are more energy efficient than the C-Cell. A saving of 10%+ No overhead crane required, A true one man installation. Exceptional anolyte flow path keeps the anode face clean. We have all seen the center erosion issue on the C-Cell anodes. This is due to a poor circulation path, combined with uneven current distribution overt the arc of the anode. |
| ThinCell Sizes up to 72" effective |
| The ThinCell can be used in bottom, side and overhead positions |
| CLICK ON THE HIGHLIGHTED TOPIC FOR MORE INFORMATION • 2X the effective anode area as the Tubular cell. • All ThinCell anodes are closed top design. • Lowest profile on the market and only 1.5” thick. • Patented encapsulation provides a strong leak proof design. • No maintenance required. • Current density 8 amps/sqft continuous, 10 amps/sqft maximum. • Integrated anolyte delivery system. • Mounts to existing strut channel, no modifications required. • Disposable design, no maintenance, parts, or rotating anodes. • Light weight design enables a true one person installation. • Fully submersible. • Long life up to 5 years without maintenance. • One year warranty* • Energy efficient, costs less to operate than tubular cells. • Installs in less than 1/3 the time as tubular cells. • Factory support and engineering for your custom needs. • Fast shipping. |
| All ThinCell and AutoCell units are now supplied with Stainless Steel Supply and Return fittings at no extra charge. The optional Heavy Duty Frames are now standard on all ThinCell and AutoCell units. |